Proof — Connected greenhouse kit
What is actually executed for this project, recalculated when this page is built.
What is tested
The kit is tested on logic, not on hardware: the SHT31 CRC, out-of-range rejection, the primary key of the database, and the watering decision conditions. These tests run on any machine.
What is executed
The commands below are executed when this page is built. They are not copied by hand: if the code changes, the proof changes or the build fails.
The limits
They are at the bottom of the page, under “What is not proven”. That is deliberately the last block, not a footnote in small print.
Tests
store/products/kit-serre/tests/test_kit.py
18 tests — OK
python3 -m unittest discover -s store/products/kit-serre/tests -q
<frozen importlib._bootstrap>:488: DeprecationWarning: builtin type SwigPyPacked has no __module__ attribute
<frozen importlib._bootstrap>:488: DeprecationWarning: builtin type SwigPyObject has no __module__ attribute
rejeté (hors plage -10.0..60.0) : serre/air/temperature = 999.0
----------------------------------------------------------------------
Ran 18 tests in 0.143s
OK
<sys>:0: DeprecationWarning: builtin type swigvarlink has no __module__ attribute
Counters
| Counters | valeur |
|---|---|
| Mesures en base serre | 120 |
Commands
Chaîne complète — publication MQTT, collecteur, SQLite
python3 store/products/kit-serre/examples/preuve.py
publiées : 5 mesures valides, 2 cas limites (valeur hors plage, topic inconnu)
en base : 5 mesure(s)
serre/air/humidite 58.0
serre/air/temperature 23.4
serre/lux 12430.0
serre/sol/humidite 41.0
serre/sol/temperature 18.9
rejets constatés :
rejeté (hors plage -10.0..60.0) : serre/air/temperature = 999.0
Décision d'arrosage — sol sec, cuve pleine, midi
python3 store/products/kit-serre/examples/decision.py --sol 20 --cuve 1 --depuis 900 --heure 12
sol 20.0 % (seuil 25 %), cuve pleine, dernier cycle il y a 900 s
heure locale 12h00 (fenêtre 6h–21h)
conditions :
sol < 25 % : oui
cuve pleine : oui
dans la fenêtre horaire : oui
délai >= 600 s : oui
décision : POMPE ON
Décision d'arrosage — cuve vide
python3 store/products/kit-serre/examples/decision.py --sol 20 --cuve 0 --depuis 900 --heure 12
sol 20.0 % (seuil 25 %), cuve vide, dernier cycle il y a 900 s
heure locale 12h00 (fenêtre 6h–21h)
conditions :
sol < 25 % : oui
cuve pleine : non
dans la fenêtre horaire : oui
délai >= 600 s : oui
décision : POMPE OFF
Files
| fichier | size | checksum |
|---|---|---|
ressources/kit-serre-guide.pdf |
61.7 Ko | cd1133de5168 |
ressources/kit-serre-v1.0.tar.gz |
72.7 Ko | 5e36149467a8 |
Images
What is not proven
- Aucun capteur n'a été branché au moment de la rédaction : les mesures publiées ici proviennent d'une base de démonstration et de publications MQTT locales.
- Le relais et la pompe n'ont pas été testés sous charge.